Basit öğe kaydını göster

dc.contributor.authorİLGÜN, Abdulkerim
dc.contributor.authorZIA, Ahmad Javid
dc.contributor.authorSANCIOĞLU, Sadrettin
dc.contributor.authorSOYDOĞAN, Hasan Furkan
dc.contributor.authorKÖKLÜ, Münife Hanım
dc.contributor.authorARIBAŞ, Semih
dc.contributor.authorBAYRAM, Berna
dc.date.accessioned2023-02-27T17:08:54Z
dc.date.available2023-02-27T17:08:54Z
dc.date.issued2023-07-05
dc.identifier.citationİlgün, A. , Zıa, A. J. , Sancıoğlu, S. , Soydoğan, H. F. , Köklü, M. H. , Arıbaş, S. & Bayram, B. (2023). Buckling performance of thin-walled filled steel columns . Turkish Journal of Engineering , 7 (3) , 172-179 . DOI: 10.31127/tuje.1092975en_US
dc.identifier.otherhttps://doi.org/10.31127/tuje.1092975
dc.identifier.urihttp://hdl.handle.net/20.500.12498/5859
dc.description.abstractConcrete-filled composite elements have recently gained popularity as beams and columns all over the world. They have advantages similar to reinforced concrete elements, such as the moulding process and the lack of maintenance of the filled concrete, as well as advantages similar to hollow steel elements, such as enhancing compressive strength and bending capacity by using smaller sections. In this paper, the buckling behaviour of thin-walled steel columns with circular cross-section and different filling materials was investigated under uniaxial load. Six different materials (concrete produced using normal aggregate, concrete produced using waste aggregate, waste fine aggregate, waste coarse aggregate, waste iron dust and polyurethane) were used as filling. Filled columns were compared experimentally with hollow thin-walled steel columns that had the same height and diameter. All specimens had the same length (750 mm), same diameter (60.3mm) and the same wall thickness (3mm). Experimental results were compared with analytical results obtained from a calculation done using the national steel design code, Design, Calculation and Construction Principles of Steel Structures 2016. Additionally, columns specimens were modelled in Abaqus software. Conservative and consistent results were obtained from comparing experimental, analytical, and numerical results.en_US
dc.language.isoenen_US
dc.publisherTurkish Journal of Engineeringen_US
dc.subjectAxial Loaden_US
dc.subjectBucklingen_US
dc.subjectColumnen_US
dc.subjectFEAen_US
dc.titleBuckling Performance of Thin-Walled Filled Steel Columnsen_US
dc.typeMakaleen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster