Basit öğe kaydını göster

dc.contributor.authorÇEVİK, Emre
dc.contributor.authorCERİT, Alaaddin
dc.contributor.authorTOMBULOĞLU, Hüseyin
dc.contributor.authorSABİT, Hussein
dc.contributor.authorYILDIZ, Hüseyin Bekir
dc.date.accessioned2019-07-09T06:03:56Z
dc.date.available2019-07-09T06:03:56Z
dc.date.issued2019-05-03
dc.identifier.urihttps://hdl.handle.net/20.500.12498/721
dc.description.abstractThe fabrication of amperometric biosensors based on whole cell Gluconobacter oxydans DSMZ 2343 (G. oxydans) and glucose oxidase (GOx) was performed for the detection of glucose. Glassy carbon electrodes (GCE) were coated with a 10-(4H-dithiyeno [3,2-b:2’,3’-d]pyroll-4-il)decan-1-amine (DTP-alkyl-NH2) polymer using an electropolymerization method and the formed interface was used to connect the bacteria and the enzyme to the electrode. The transfer of electrons from enzyme to electrode was successfully demonstrated by the biocatalytic activity and unique morphology of the conducting polymer. Characterization of the biosensors was assessed using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and scanning electron microscopy (SEM) analyses. The detection limits of the enzyme and microbial based biosensors for glucose were 0.022 and 0.081 mM, respectively. The broad linear dynamic ranges of the GOx and G. oxydans biosensors were observed to be 0.045–50.0 and 0.19–50.0 mM, respectively. The analytical performances of biosensors were compared according to the following figures of merit: detection limits, limits of quantification, pH and current response time. In addition, to demonstrate the applicability of the biosensors, real-time measurements and recovery studies were evaluated.en_US
dc.description.sponsorshipThe authors would like to thank the European Union through the COST Action CM1104 “Reducible Oxide Chemistry, Structure and Functions” and the Scientific and Technological Research Council of Turkey (TUBITAK Grant Number 112T622) for the financial support of this work.en_US
dc.language.isoen_USen_US
dc.publisherTaylor and Francisen_US
dc.subjectGlucose Biosensoren_US
dc.subjectGlucose Oxidaseen_US
dc.subjectG. Oxydansen_US
dc.subject10-(4H-dithiyeno[3,2-b:2′, 3′-d]pyroll-4-il)decan-1-amine (DTP) Conducting Polymeren_US
dc.subjectWhole Cell Microbial Biosensoren_US
dc.titleElectrochemical Glucose Biosensors: Whole Cell Microbial and Enzymatic Determination Based on 10-(4H-Dithieno[3,2-b:2′,3′-d]Pyrrol-4-yl)Decan-1-Amine Interfaced Glassy Carbon Electrodesen_US
dc.typeMakaleen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster