Basit öğe kaydını göster

dc.contributor.authorGÖKOĞLAN, Tuğba Ceren
dc.contributor.authorSÖYLEMEZ, Saniye
dc.contributor.authorKESİK, Melis
dc.contributor.authorÜNAY, Hande
dc.contributor.authorSAYIN, Serkan
dc.contributor.authorYILDIZ, Hüseyin Bekir
dc.contributor.authorÇIRPAN, Ali
dc.contributor.authorTOPPARE, Levent
dc.date.accessioned2020-08-07T13:00:40Z
dc.date.available2020-08-07T13:00:40Z
dc.date.issued2015
dc.identifier10.1039/c5ra03933a
dc.identifier.issn20462069 (ISSN)
dc.identifier.urihttp://hdl.handle.net/20.500.12498/3107
dc.description.abstractIn this study, a novel amperometric glucose biosensor based on a selenium comprising conducting polymer and calixarene was developed. Firstly, poly(2-(2-octyldodecyl)-4,7-di(selenoph-2-yl)-2H-benzo[d][1,2,3]triazole), poly((SBTz)) was electrodeposited onto a graphite electrode by an electropolymerization technique. Then, a newly synthesized calixarene and gold nanoparticle (AuNP) mixture was used for the improvement of biosensor characteristics. GOx, as a model enzyme was immobilized on the modified electrode surface. The constructed surface serves as a sufficient immobilization platform for the detection of glucose. Calixarenes and their derivatives may be a favouring agent for enzyme immobilization due to their specific configurations. Moreover, through the covalent binding between the carboxylic groups of the calixarenes and amino groups of the biomolecule, effective enzyme immobilization can be achieved while protecting the well-ordered structure of the enzyme molecule. Amperometric detection was carried out following oxygen consumption at -0.7 V vs. the Ag reference electrode in phosphate buffer (50 mM, pH 6.5). The proposed biosensor showed a linear amperometric response for glucose within a concentration range of 0.005 to 0.5 mM (LOD: 0.004 mM). Kappm and sensitivity were calculated as 0.025 mM and 102 μA mM-1 cm-2, respectively. Scanning Electron Microscopy (SEM) was used to investigate the surface morphologies of successive modifications. Finally, the constructed biosensor was tested successfully to detect glucose in beverage samples. © The Royal Society of Chemistry 20153.
dc.language.isoEnglish
dc.publisherRoyal Society of Chemistry
dc.sourceRSC Advances
dc.titleA Novel Architecture Based On A Conducting Polymer And Calixarene Derivative: İts Synthesis And Biosensor Construction
dc.typeMakale


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster